Novel rapid in vitro cytotoxicity test on mammalian cells based on an electrochemical measuring method

Logo poskytovatele

Varování

Publikace nespadá pod Filozofickou fakultu, ale pod Přírodovědeckou fakultu. Oficiální stránka publikace je na webu muni.cz.
Autoři

PESCHECK michael DURR Constanze BLÁHA Luděk SELL Dieter

Rok publikování 2014
Druh Článek v odborném periodiku
Časopis / Zdroj JOURNAL OF APPLIED ELECTROCHEMISTRY
Fakulta / Pracoviště MU

Přírodovědecká fakulta

Citace
www http://link.springer.com/article/10.1007%2Fs10800-014-0707-x
Doi http://dx.doi.org/10.1007/s10800-014-0707-x
Obor Vliv životního prostředí na zdraví
Klíčová slova Bioelectrochemistry; Mediator; Cytotoxicity; IC50; Cytotoxicity test; Toxicological risk; Bioactivity sensor
Popis The proliferation of pharmaceuticals and chemicals and the increasing manufacture of medical goods have made an assessment of their potential toxicological risks to man and the environment indispensable. Hence, a wide range of tests has been developed in order to generate data on the harmful effects of chemicals and pharmaceuticals on organisms. Initially, toxicological data were commonly collected from tests involving animals; however, on account of ethical objections, they are gradually being replaced by in vitro cytotoxicity tests. In this work, a new in vitro screening method for the determination of cytotoxicity, based on a novel electrochemical bioactivity sensor system, was implemented. The evaluation was based on current-time curves of a potentiostatic measurement proportional to the reduction of mediator molecules by mammalian cells. Depending on the number of reduced mediator molecules used by the cells, a current signal is produced, which provides information about the viability of living cells. By adding a toxic test substance to the cell, a reduction in the current signal can be observed, depending on the cytotoxicity of the substance. It is possible to quickly create a specific cytotoxic curve and to determine the corresponding inhibitory concentrations (IC50 value). First tests were performed on three mammalian cell lines and eight model compounds using this electrochemical measurement system. The IC50 values obtained corresponded well with the toxicity determined with an established reference cytotoxicity assay (MTT test) and with data reported in the literature.
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.